Kit "Make-A-Berm" cubierto de PVC, flexible y resistente al aplastamiento
Quickly go to
Vista general
Product features
  • Múltiples componentes de Make-A-Berm
  • Las piezas rectas pueden ser unidas o combinadas con las esquinas para crear una solución de contención completa
  • Capacidad de cortar fácilmente los trozos de berma con un cuchillo para adaptarse a la zona de contención
  • Contiene derrames y fugas alrededor de situaciones de equipo únicas
  • Color amarillo brillante y duradero para la visibilidad
  • Diferentes tamaños ideales para las necesidades de contención de pequeña y mediana capacidad
  • Regulatory Compliance – Designed to help facilities meet EPA 40 CFR 264.175 and SPCC spill containment regulations.
Product description
El kit de Make-A-Berm™ es adecuado para la mayoría de las necesidades de aplicación. Puede ser fácilmente instalado en el sitio para adaptarse a la disposición sin tener que mover el equipo existente. Conecta varias piezas de berma para que se ajusten a su área de contención. La tela recubierta de PVC modificado no absorbente proporciona una barrera altamente resistente para contener aceites, gasolina, ácidos y otros líquidos. Para un sellado a prueba de líquidos, se dispone de una instalación semipermanente en el suelo con el uso de un adhesivo a base de poliéter. Los insertos de espuma flexible son resistentes a la compresión y vuelven a su forma original sin pérdida de memoria después del uso de equipos de tráfico a pie o de carretillas.
Cumplimientos
EPA CFR 40
EPA
EPA CFR 40
264.175 Containment. (a) Container storage areas must have a containment system that is designed and operated in accordance with paragraph (b) of this section, except as otherwise provided by paragraph (c) of this section. (b) A containment system must be designed and operated as follows: (1) A base must underlie the containers which is free of cracks or gaps and is sufficiently impervious to contain leaks, spills, and accumulated precipitation until the collected material is detected and removed; (2) The base must be sloped or the containment system must be otherwise designed and operated to drain and remove liquids resulting from leaks, spills, or precipitation, unless the containers are elevated or are otherwise protected from contact with accumulated liquids; (3) The containment system must have sufficient capacity to contain 10% of the volume of containers or the volume of the largest container, whichever is greater. Containers that do not contain free liquids need not be considered in this determination; (4) Run-on into the containment system must be prevented unless the collection system has sufficient excess capacity in addition to that required in paragraph (b)(3) of this section to contain any run-on which might enter the system; and (5) Spilled or leaked waste and accumulated precipitation must be removed from the sump or collection area in as timely a manner as is necessary to prevent overflow of the collection system. (c) Storage areas that store containers holding only wastes that do not contain free liquids need not have a containment system defined by paragraph (b) of this section, except as provided by paragraph (d) of this section or provided that: (1) The storage area is sloped or is otherwise designed and operated to drain and remove liquid resulting from precipitation, or (2) The containers are elevated or are otherwise protected from contact with accumulated liquid. (d) Storage areas that store containers holding the wastes listed below that do not contain free liquids must have a containment system defined by paragraph (b) of this section: (1) FO20, FO21, FO22, FO23, FO26, and FO27. (2) [Reserved]
Especificaciones Técnicas
especificaciones-tecnicas-generales
Drive In No
High Hazard Seismic Zone No