Estaciones de descontaminación multi-zona portátiles. Ayudan a prevenir la contaminación medioambiental
Quickly go to
Vista general
Product features
- Para despliegues de emergencia, estas cubetas multiplataforma con paredes interiores patentadas crean zonas de lavado que recogen y contienen soluciones contaminadas de forma segura. Seleccione entre modelos de dos, tres o cuatro zonas
- La lona ligera recubierta de en PVC proporciona una resistencia a un amplio rango de materiales químicos. Las paredes de 20 cm permiten una entrada y salida rápida de los compartimentos y un drenaje de 19 mm GHT por zona
- Construcción en una pieza — sistema de soporte de pared patentado forma unas zonas de lavado estancas
- Instalación rápida y fácil – sin necesidad de ensamblaje
- Rejillas antideslizamiento duraderas opcionales para mantener al personal y piezas por encima del agua de lavado, lejos de fluidos y contaminantes
- Secure and Compliant: Ensures a safe wash-down area that meets environmental protection standards.
Product description
Portable multi-zone decon stations help prevent environmental contamination. Single-piece construction—patented inside wall-support system forms watertight wash down zones. Quick and easy setup—no assembly required. For emergency deployment, these multi-stage berms with patented interior walls create wash down zones that safely capture and contain contaminated solutions. Select from two-, three-, or four-zone models. Watertight, lightweight PVC coated fabric provides wide range of chemical resistance. The 8-inch (203-mm) walls allow for easy entry and exit of the compartments. One ¾-in GHT drain fitting per zone. Order optional grates to keep personnel above liquid.
Cumplimientos
EPA CFR 40
EPA CFR 40
264.175 Containment. (a) Container storage areas must have a containment system that is designed and operated in accordance with paragraph (b) of this section, except as otherwise provided by paragraph (c) of this section. (b) A containment system must be designed and operated as follows: (1) A base must underlie the containers which is free of cracks or gaps and is sufficiently impervious to contain leaks, spills, and accumulated precipitation until the collected material is detected and removed; (2) The base must be sloped or the containment system must be otherwise designed and operated to drain and remove liquids resulting from leaks, spills, or precipitation, unless the containers are elevated or are otherwise protected from contact with accumulated liquids; (3) The containment system must have sufficient capacity to contain 10% of the volume of containers or the volume of the largest container, whichever is greater. Containers that do not contain free liquids need not be considered in this determination; (4) Run-on into the containment system must be prevented unless the collection system has sufficient excess capacity in addition to that required in paragraph (b)(3) of this section to contain any run-on which might enter the system; and (5) Spilled or leaked waste and accumulated precipitation must be removed from the sump or collection area in as timely a manner as is necessary to prevent overflow of the collection system. (c) Storage areas that store containers holding only wastes that do not contain free liquids need not have a containment system defined by paragraph (b) of this section, except as provided by paragraph (d) of this section or provided that: (1) The storage area is sloped or is otherwise designed and operated to drain and remove liquid resulting from precipitation, or (2) The containers are elevated or are otherwise protected from contact with accumulated liquid. (d) Storage areas that store containers holding the wastes listed below that do not contain free liquids must have a containment system defined by paragraph (b) of this section: (1) FO20, FO21, FO22, FO23, FO26, and FO27. (2) [Reserved]
Especificaciones Técnicas
especificaciones-tecnicas-generales
| High Hazard Seismic Zone | No |
|---|---|
| Material Group | PVC |