Please ensure Javascript is enabled for purposes of website accessibility
Elija la marca para la que desea ver la tienda web

Absorbentes para fugas y goteos 2846 Justrite

Art. no: 2846
Product description
Recoge pequeñas fugas o goteos de aceite antes de que contaminen el suelo o conviertan en peligrosa una superficie de trabajo
Quickly go to
Vista general
Product features
  • Fabricado en PVC modificado resistente a los rayos UV y materiales químicos
  • El diseño patentado incluye una capa exterior de malla recubierta para atrapar residuos grandes
  • Absorbente solo de aceites, sustituible, dentro de una barrera impermeable soldada
  • Apropiado para aplicaciones en automoción, los empapadores incluyen arandelas de latón en las esquinas opuestas para poder anclarlos. Estacas de anclaje no incluidas
  • Los empapadores vienen en dos tamaños; el modelo extendido está lastrado para que no se vuele con vientos fuertes. La cubierta exterior es reutilizable con los paquetes de relleno sorbente opcionales
  • Anchoring Grommets: Equipped with brass grommets in opposing corners for secure anchoring (stakes not included).
  • Multiple Sizes: Offered in standard and extended models, with the extended model weighted for stability in high winds.
Product description
Recogen pequeñas fugas de aceite o goteos antes de que contaminen el suelo o creen una superficie de trabajo peligrosa. Ligero, flexible y portátil: ideal para contener pequeños goteos de aceite de vehículos con fugas, equipos de maquinaria industrial, líneas hidráulicas, tuberías y tambores. Fabricado con PVC modificado resistente a los rayos UV y a los productos químicos. El diseño patentado incluye una capa exterior de malla revestida para atrapar los residuos gruesos. Estas almohadillas antigoteo cuentan con un sorbente reemplazable solo con aceite dentro de una barrera soldada a prueba de fugas. Apropiado para aplicaciones en automoción, los empapadores incluyen arandelas de latón en las esquinas opuestas para poder anclarlos. Estacas de anclaje no incluidas. Los empapadores vienen en dos tamaños; el modelo extendido está lastrado para que no se vuele con vientos fuertes. La cubierta exterior es reutilizable con los paquetes sorbentes de recarga opcionales. Ayuda a cumplir con la EPA para la prevención de derrames (SPCC).
Cumplimientos
EPA CFR 40
EPA
EPA CFR 40
264.175 Containment. (a) Container storage areas must have a containment system that is designed and operated in accordance with paragraph (b) of this section, except as otherwise provided by paragraph (c) of this section. (b) A containment system must be designed and operated as follows: (1) A base must underlie the containers which is free of cracks or gaps and is sufficiently impervious to contain leaks, spills, and accumulated precipitation until the collected material is detected and removed; (2) The base must be sloped or the containment system must be otherwise designed and operated to drain and remove liquids resulting from leaks, spills, or precipitation, unless the containers are elevated or are otherwise protected from contact with accumulated liquids; (3) The containment system must have sufficient capacity to contain 10% of the volume of containers or the volume of the largest container, whichever is greater. Containers that do not contain free liquids need not be considered in this determination; (4) Run-on into the containment system must be prevented unless the collection system has sufficient excess capacity in addition to that required in paragraph (b)(3) of this section to contain any run-on which might enter the system; and (5) Spilled or leaked waste and accumulated precipitation must be removed from the sump or collection area in as timely a manner as is necessary to prevent overflow of the collection system. (c) Storage areas that store containers holding only wastes that do not contain free liquids need not have a containment system defined by paragraph (b) of this section, except as provided by paragraph (d) of this section or provided that: (1) The storage area is sloped or is otherwise designed and operated to drain and remove liquid resulting from precipitation, or (2) The containers are elevated or are otherwise protected from contact with accumulated liquid. (d) Storage areas that store containers holding the wastes listed below that do not contain free liquids must have a containment system defined by paragraph (b) of this section: (1) FO20, FO21, FO22, FO23, FO26, and FO27. (2) [Reserved]
Especificaciones Técnicas
especificaciones-tecnicas-generales
High Hazard Seismic Zone No
Material Group PVC