Please ensure Javascript is enabled for purposes of website accessibility
Kies het merk waarvan je de webshop wilt bekijken

Make-A-Berm Kit MAB-KIT Justrite

Artnr: MAB-KIT
Productbeschrijving
PVC gecoate, flexibele en pletbestendige Make-A-Berm™ Kit
Quickly go to
Overzicht
Technische specificaties
  • Meerdere Make-A-Berm™ onderdelen
  • De rechte secties kunnen met elkaar of met de hoeksecties verbonden worden om zo een complete opvangoplossing te creëren
  • De berm secties kunnen eenvoudig met een mes op maat gesneden worden om deze aan te passen aan de opvangzone
  • Damt lekkages en gemorste vloeistoffen in rond unieke machine opstellingen
  • Slijtvaste felle gele kleur voor goede zichtbaarheid
  • Verschillende maten, ideaal voor opvangzones met kleine tot middelgrote capaciteit
  • Regulatory Compliance – Designed to help facilities meet EPA 40 CFR 264.175 and SPCC spill containment regulations.
Productbeschrijving
De Make-A-Berm™ Kit is geschikt voor de meeste toepassingsvereisten. Hij kan eenvoudig ter plaatse geïnstalleerd en aangepast worden aan de bestaande lay-out, zonder reeds aanwezige machines te hoeven verplaatsen. Verbind meerdere berm secties om deze aan te passen aan uw opvangzone. De niet-absorberende met gemodificeerde PVC gecoate stof biedt een zeer resistente barrière voor het indammen van olie, benzine, zuren en andere vloeistoffen. Voor een vloeistofdichte afdekking is een semi-permanente installatie op de vloer mogelijk, met behulp van een lijm op basis van polyether. De flexibele schuimkern is pletbestendig en keert steeds weer terug naar zijn originele vorm nadat deze is ingedrukt door de passage van personen of handkarren.
Compliances
EPA CFR 40
EPA
EPA CFR 40
264.175 Containment. (a) Container storage areas must have a containment system that is designed and operated in accordance with paragraph (b) of this section, except as otherwise provided by paragraph (c) of this section. (b) A containment system must be designed and operated as follows: (1) A base must underlie the containers which is free of cracks or gaps and is sufficiently impervious to contain leaks, spills, and accumulated precipitation until the collected material is detected and removed; (2) The base must be sloped or the containment system must be otherwise designed and operated to drain and remove liquids resulting from leaks, spills, or precipitation, unless the containers are elevated or are otherwise protected from contact with accumulated liquids; (3) The containment system must have sufficient capacity to contain 10% of the volume of containers or the volume of the largest container, whichever is greater. Containers that do not contain free liquids need not be considered in this determination; (4) Run-on into the containment system must be prevented unless the collection system has sufficient excess capacity in addition to that required in paragraph (b)(3) of this section to contain any run-on which might enter the system; and (5) Spilled or leaked waste and accumulated precipitation must be removed from the sump or collection area in as timely a manner as is necessary to prevent overflow of the collection system. (c) Storage areas that store containers holding only wastes that do not contain free liquids need not have a containment system defined by paragraph (b) of this section, except as provided by paragraph (d) of this section or provided that: (1) The storage area is sloped or is otherwise designed and operated to drain and remove liquid resulting from precipitation, or (2) The containers are elevated or are otherwise protected from contact with accumulated liquid. (d) Storage areas that store containers holding the wastes listed below that do not contain free liquids must have a containment system defined by paragraph (b) of this section: (1) FO20, FO21, FO22, FO23, FO26, and FO27. (2) [Reserved]
Technische Specificaties
Algemene specificaties
Berijdbaar Nee
High Hazard Seismic Zone Nee