Arte. no: 2858
Descrizione del prodotto
Portable drive-through station captures contaminated water from vehicle and construction equipment wash down.
Quickly go to
Panoramica
Caratteristiche del prodotto
  • Robusto materiale rivestito in vinile rinforzato con strisce gialle indicatrici ad alta visibilità saldate a radiofrequenza, resistente al passaggio di veicoli, compresi terne e minipale
  • Gli inserti rimovibili in schiuma da 102 mm di diametro supportano le pareti laterali, mentre le lastre da 51 x 203 mm (non incluse) scorrono nelle tasche per mantenere le pareti sollevate alle estremità, evitando che le acque di scarico fuoriescano durante il passaggio dei veicoli. È sufficiente rimuovere gli inserti in schiuma per piegare il materiale e poterlo riporre in modo rapido e compatto
  • Due raccordi DN25 NPT su ciascun lato del sistema di contenimento per il drenaggio
  • Gli occhielli in ottone intorno al perimetro offrono la possibilità di ancorare saldamente il sistema di contenimento durante l'utilizzo. Pali di ancoraggio non inclusi
  • È di aiuto per la conformità EPA per le normative sulle acque piovane
  • Regulatory Compliance: Designed to help comply with EPA stormwater regulations, protecting waterways from harmful runoff.
  • Secure Anchoring: Brass grommets around the perimeter provide anchoring points for stability during use (stakes not included).
Descrizione del prodotto
Portable drive-through station captures contaminated water from vehicle and construction equipment wash down. Durable vinyl coated material reinforced with radio frequency-welded, high visibility yellow runway strips that withstand drive-thru traffic, including backhoes and skid steers. Removable 4-in (102-mm) diameter foam inserts support sidewalls while 2-in H x 8-in W (51- x 203-mm) planks (not included) slide into pockets to keep end walls elevated preventing wastewater from escaping during drive-over. Simply remove foam inserts to fold material for quick and compact storage. Two 1-in NPT fittings on each side of the berm for drainage. Brass grommets around perimeter provide the ability to securely anchor berm during use. Anchor stakes not included. Helps comply with EPA for stormwater regulations.
Conformità
EPA CFR 40
EPA
EPA CFR 40
264.175 Containment. (a) Container storage areas must have a containment system that is designed and operated in accordance with paragraph (b) of this section, except as otherwise provided by paragraph (c) of this section. (b) A containment system must be designed and operated as follows: (1) A base must underlie the containers which is free of cracks or gaps and is sufficiently impervious to contain leaks, spills, and accumulated precipitation until the collected material is detected and removed; (2) The base must be sloped or the containment system must be otherwise designed and operated to drain and remove liquids resulting from leaks, spills, or precipitation, unless the containers are elevated or are otherwise protected from contact with accumulated liquids; (3) The containment system must have sufficient capacity to contain 10% of the volume of containers or the volume of the largest container, whichever is greater. Containers that do not contain free liquids need not be considered in this determination; (4) Run-on into the containment system must be prevented unless the collection system has sufficient excess capacity in addition to that required in paragraph (b)(3) of this section to contain any run-on which might enter the system; and (5) Spilled or leaked waste and accumulated precipitation must be removed from the sump or collection area in as timely a manner as is necessary to prevent overflow of the collection system. (c) Storage areas that store containers holding only wastes that do not contain free liquids need not have a containment system defined by paragraph (b) of this section, except as provided by paragraph (d) of this section or provided that: (1) The storage area is sloped or is otherwise designed and operated to drain and remove liquid resulting from precipitation, or (2) The containers are elevated or are otherwise protected from contact with accumulated liquid. (d) Storage areas that store containers holding the wastes listed below that do not contain free liquids must have a containment system defined by paragraph (b) of this section: (1) FO20, FO21, FO22, FO23, FO26, and FO27. (2) [Reserved]
Specifiche Tecniche
Specifiche generali
High Hazard Seismic Zone No