Please ensure Javascript is enabled for purposes of website accessibility
Scegli il marchio per il quale desideri visualizzare il negozio online

Decon QuickBerm® 2857 Justrite

Arte. no: 2857
Descrizione del prodotto
Portable decontamination solution with multiple wash-down zones, designed to protect personnel and contain hazardous fluids during emergency response operations
Quickly go to
Panoramica
Caratteristiche del prodotto
  • Per uso in caso di emergenza, questi sistemi di contenimento multizona con pareti interne brevettate creano zone di lavaggio che catturano e contengono in modo sicuro le soluzioni contaminate. Selezionabili in modelli da due, tre o quattro zone
  • Il tessuto leggero rivestito in PVC offre resistenza a un’ampia gamma di sostanze chimiche. Le pareti da 20 cm consentono il facile inserimento e la rimozione degli scompartimenti. Raccordo di drenaggio GHT da 19 mm per zona
  • Struttura monoblocco; il sistema interno di supporto a parete brevettato crea zone di lavaggio impermeabili
  • Installazione semplice e rapida: nessun assemblaggio richiesto
  • Le griglie resistenti e antiscivolo opzionali permettono di allontanare il personale e le parti dai liquidi e dai contaminanti; questi ultimi restano nell’acqua di lavaggio contaminata
  • Secure and Compliant: Ensures a safe wash-down area that meets environmental protection standards.
Descrizione del prodotto
Portable multi-zone decon stations help prevent environmental contamination. Single-piece construction—patented inside wall-support system forms watertight wash down zones. Quick and easy setup—no assembly required. For emergency deployment, these multi-stage berms with patented interior walls create wash down zones that safely capture and contain contaminated solutions. Select from two-, three-, or four-zone models. Watertight, lightweight PVC coated fabric provides wide range of chemical resistance. The 8-inch (203-mm) walls allow for easy entry and exit of the compartments. One ¾-in GHT drain fitting per zone. Order optional grates to keep personnel above liquid.
Conformità
EPA CFR 40
EPA
EPA CFR 40
264.175 Containment. (a) Container storage areas must have a containment system that is designed and operated in accordance with paragraph (b) of this section, except as otherwise provided by paragraph (c) of this section. (b) A containment system must be designed and operated as follows: (1) A base must underlie the containers which is free of cracks or gaps and is sufficiently impervious to contain leaks, spills, and accumulated precipitation until the collected material is detected and removed; (2) The base must be sloped or the containment system must be otherwise designed and operated to drain and remove liquids resulting from leaks, spills, or precipitation, unless the containers are elevated or are otherwise protected from contact with accumulated liquids; (3) The containment system must have sufficient capacity to contain 10% of the volume of containers or the volume of the largest container, whichever is greater. Containers that do not contain free liquids need not be considered in this determination; (4) Run-on into the containment system must be prevented unless the collection system has sufficient excess capacity in addition to that required in paragraph (b)(3) of this section to contain any run-on which might enter the system; and (5) Spilled or leaked waste and accumulated precipitation must be removed from the sump or collection area in as timely a manner as is necessary to prevent overflow of the collection system. (c) Storage areas that store containers holding only wastes that do not contain free liquids need not have a containment system defined by paragraph (b) of this section, except as provided by paragraph (d) of this section or provided that: (1) The storage area is sloped or is otherwise designed and operated to drain and remove liquid resulting from precipitation, or (2) The containers are elevated or are otherwise protected from contact with accumulated liquid. (d) Storage areas that store containers holding the wastes listed below that do not contain free liquids must have a containment system defined by paragraph (b) of this section: (1) FO20, FO21, FO22, FO23, FO26, and FO27. (2) [Reserved]
Specifiche Tecniche
Specifiche generali
High Hazard Seismic Zone No
Material Group PVC